There are significant opportunities in most of the cement plants to improve their energy efficiency as the gap between the best performing plant and the other plants is still large (difference of 10-12 kWh/MT cement and 50-80 kcal/kg clinker).
This Benchmarking tool will help cement plants to understand the extent of difference in their performance as compared to the best performing plants, as well as the root cause for the differences.

The best-operating values and the outcome of the benchmarking study are as follows

BENCHMARKING NUMBERS
Sr. No. Section Unit Value
1 Emission Intensity Kg CO2/MT Cement 285
2 SEC Upto Clinkerisation kWh/MT Clinker 42.1
3 SEC Grinding + Packing kWh/MT Cement 18.62
4 Overall SEC Kg CO2/MT Cement 56.1
5 SP. Heat Consumption kCal/Kg Clinker 67.5
6 Clinker Factor 0.55
7 Renewable Energy % of overall Electrical Energy 24
8 Average power generation through WHR kWh/MT Clinker 32
9 Alternate Fuel ( Thermal Substitution Rate ) % % 35
10 No. Of Preheater Stages 6
11 Share of CPP ,Grid,WHR and RE in Overall Power Consumption CPP : GRID : WHR : RE 23 : 31 : 21 : 18
12 Major Product - PSC